White Papers
10 Version 1.1.0
7 Implementation Description
This section describes the requirements and guidelines for implementing Dell iDRAC Card Profile.
Table 2 – Class Requirements: iDRAC Card Profile
Element Name
Requirement
Description
Classes
DCIM_IDRACCardView
Mandatory
The class shall be implemented in the
Implementation Namespace.
See section 7.1.
DCIM_iDRACCardAttribute
Mandatory
The class shall be implemented in the
Implementation Namespace.
See section 7.2.
DCIM_iDRACCardInteger
Mandatory
The class shall be implemented in the
Implementation Namespace.
See section 7.3.
DCIM_iDRACCardService
Mandatory
The class shall be implemented in the
Implementation Namespace.
See section 7.4.
DCIM_iDRACCardEnumeration
Mandatory
The class shall be implemented in the
Implementation Namespace.
See section 7.5.
DCIM_iDRACCardString
Mandatory
The class shall be implemented in the
Implementation Namespace.
See section 7.6.
DCIM_LCElementConformsToProfile
Mandatory
The class shall be implemented in the
Implementation Namespace.
DCIM_LCElementConformsToProfile
Mandatory
The class shall be implemented in the
Interop Namespace.
DCIM_LCRegisteredProfile
Mandatory
The class shall be implemented in the
Interop Namespace.
See section 7.7.
Indications
None defined in this profile
7.1 iDrac View
This section describes the implementation for the DCIM_IDRACCardView class.
This class shall be instantiated in the Implementation Namespace.
The DCIM_LCElementConformsToProfile association(s) shall reference the DCIM_IDRACCardView
instance(s).
7.1.1 WBEM URIs for WinRM
®
The class WBEM URI shall be “http://schemas.dell.com/wbem/wscim/1/cim-
schema/2/DCIM_IDRACCardView?__cimnamespace=<Implementation Namespace>”
The key property shall be the InstanceID.