Developers Guide
Preparing PS Series volumes for import
28 Data Migration from Dell PS Series or PowerVault MD3 to Dell EMC SC Series Storage using Thin Import | 3041-BP-EM
3. The newly selected volumes now appear in the Targets area.
3.3 Allow simultaneous iSCSI connections to volumes
By default, PS Series volumes allow access to a single iSCSI initiator. When connected to a PS Series array,
each individual SC Series iSCSI network connection is treated as a separate initiator. In order for all available
paths from the SC Series array to connect to the PS Series volume, the volume must be configured to allow
simultaneous connections from multiple initiators.
Note: Repeat the following steps for each PS Series volume that will be imported to the SC Series array.
1. Log in to EqualLogic Group Manager using group administrator credentials.
2. Click Volumes.
3. In the Volumes subtree, select a volume to modify.