Developers Guide

Preparing PS Series volumes for import
11 Data Migration from Dell PS Series or PowerVault MD3 to Dell EMC SC Series Storage using Thin Import | 3041-BP-EM
Note: The Dell Storage Client can connect to a Dell Storage Manager Data Collector or connect directly to an
SC Series array. The instructions in this section focus only on connecting directly to an SC Series array.
2. Log in to the Dell Storage Client with administrative credentials.
3. Open the Storage tab and navigate to Fault Domains > iSCSI. Select the iSCSI fault domain that will
be used for the import process.
Note: On systems with more than one iSCSI fault domain, select a fault domain that is configured on the
same network as the PS Series array.
4. In the iSCSI fault domain area, locate and record the IP addresses or iSCSI names of all listed
physical ports.
Note: Be sure to use the physical port IP addresses or iSCSI names, as using the virtual port information will
not allow the import process.