White Papers
34 Version 1.0.0
Property Name
Type
Requirement
Additional Requirements
ChangeType
uint16
Mandatory
The property shall have value
4 (Gauge)
DataType
uint16
Mandatory
The property shall have value
12 (uint32)
ElementName
string
Mandatory
The property shall have value
“Instantaneous Power”
GatheringType
uint16
Mandatory
The property shall have value
3 (periodic)
Id
string
Mandatory
The property shall have value
“DCIM:System:Point:Power”
IsContinuous
boolean
Mandatory
The property shall have value
TRUE
Name
string
Mandatory
The property shall have value
"DMTF:System Input Power"
ProgrammaticUnits
string
Mandatory
The property shall have value
"watt"
SampleInterval
datetime
Mandatory
The property shall be in W3C
representation in WS-CIM
with the corresponding value
equal to
00000000000500.000000:000
in CIM datetime format.
TimeScope
uint16
Mandatory
The property shall have value
2 (Point)
695
696
7.8.2 DCIM_BaseMetricValue 697
The following clauses define the requirements for the DCIM_BaseMetricValue class. 698
DCIM_BaseMetricValue is derived from CIM_BaseMetricValue. 699
7.8.2.1 Resource URIs for WinRM® 700
The class Resource URI shall be “http://schemas.dell.com/wbem/wscim/1/cim-701
schema/2/DCIM_BaseMetricValue?__cimnamespace=root/dcim” 702
The key property shall be the InstanceID. 703
The instance Resource URI for this DCIM_BaseMetricValue instance shall be: 704
“http://schemas.dell.com/wbem/wscim/1/cim-schema/2/DCIM_BaseMetricValue? 705
?__cimnamespace=root/dcim+InstanceID=<InstanceID>” 706
7.8.2.2 Operations 707
The following table details the implemented operations on DCIM_BaseMetricValue. 708
Table 31 – DCIM_BaseMetricValue Operations 709
Operation Name
Requirements
Required Input
Get
Mandatory
Instance URI
Enumerate
Mandatory
Class URI
Associators
Mandatory
Instance URI