White Papers

32 Version 1.0.0
7.7.2 DCIM_BaseMetricValue 647
The following clauses define the requirements for the DCIM_BaseMetricValue class. 648
DCIM_BaseMetricValue is derived from CIM_BaseMetricValue. 649
The DCIM_BaseMetricInstance association’s Dependent property shall reference 650
DCIM_AggregationMetricValue instances. 651
The DCIM_MetricForME association’s Dependent property shall reference 652
DCIM_AggregationMetricValue instances. 653
7.7.2.1 Resource URIs for WinRM® 654
The class Resource URI shall be “http://schemas.dell.com/wbem/wscim/1/cim-655
schema/2/DCIM_BaseMetricValue?__cimnamespace=root/dcim” 656
The key property shall be the InstanceID. 657
The instance Resource URI for this DCIM_BaseMetricValue instance shall be: 658
http://schemas.dell.com/wbem/wscim/1/cim-schema/2/DCIM_BaseMetricValue? 659
?__cimnamespace=root/dcim+InstanceID=<InstanceID>” 660
7.7.2.2 Operations 661
The following table details the implemented operations on DCIM_BaseMetricValue. 662
Table 27DCIM_BaseMetricValue Operations 663
Operation Name
Requirements
Get
Mandatory
Enumerate
Mandatory
Associators
Mandatory
References
Mandatory
7.7.2.3 Properties 664
The following table details the requirements for implementing DCIM_BaseMetricValue instance 665
representing energy consumption metric. The most derived class name of this instance shall be 666
DCIM_BaseMetricValue. 667
If the column “Property Name” matches the property name, the property either shall have the value 668
denoted in the corresponding column “Additional Requirements, or shall be implemented according to 669
the requirements in the corresponding column “Additional Requirements. 670
Table 28DCIM_BaseMetricValue: Energy Consumption Metric in Amperes Properties 671
Property Name
Type
Requirement
Additional Requirements
Duration
datetime
Mandatory
The property shall be in W3C
representation in WS-CIM with the
corresponding value equal to
Current timestamp minus Start
Time of cumulative reading
InstanceID
string
Mandatory
The property shall have value
DCIM:System:Point:Energy:Cont
MetricDefinitionId
string
Mandatory
The property shall have value
DCIM:BaseMetricDefinition:1
MetricValue
string
Mandatory
The property shall have value be
equal to the value of the