7.7.1.2 Operations 636
The following table details the implemented operations on DCIM_BaseMetricDefinition. 637
Table 25 – DCIM_BaseMetricDefinition Operations 638
Operation Name
Requirements
Required Input
Get Mandatory Instance URI
Enumerate
Mandatory
Class URI
Associators
Mandatory
Instance URI
References
Mandatory
Instance URI
7.7.1.3 Properties 639
The following table details the requirements for implementing DCIM_BaseMetricDefinition instance 640
representing energy consumption metric. The most derived class name of this instance shall be 641
DCIM_BaseMetricDefinition. 642
If the column “Property Name” matches the property name, the property either shall have the value 643
denoted in the corresponding column “Additional Requirements”, or shall be implemented according to 644
the requirements in the corresponding column “Additional Requirements”. 645
Table 26 – DCIM_BaseMetricDefinition: Energy Consumption Metric Properties 646
Property Name
Type
Requirement
Additional Requirements
ChangeType
uint16
Mandatory
The property shall have value
3 (Counter)
DataType
uint16
Mandatory
The property shall have value
12 (uint32)
ElementName
string
Mandatory
The property shall have value
“Energy Consumption”
GatheringType
uint16
Mandatory
The property shall have value
3 (periodic)
Id
string
Mandatory
The property shall have value
“DCIM:BaseMetricDefinition:1”
IsContinuous
boolean
Mandatory
The property shall have value
TRUE.
Name
string
Mandatory
The property shall have value
"DMTF:System Aggregate
Input Energy"
ProgrammaticUnits
string
Mandatory
The property shall have value
"watt * hour * 10^3"
SampleInterval
datetime
Mandatory
The property shall be in W3C
representation in WS-CIM
with the corresponding value
equal to
00000000000500.000000:000
in CIM datetime format.
TimeScope
uint16
Mandatory
The property shall have value
4 (Startup Interval).