White Papers

Version 1.0.0 29
Property Name
Type
Requirement
Additional Requirements
GatheringType
uint16
Mandatory
The property shall have value 3 (periodic)
Id
string
Mandatory
The property shall have value “AggrMetricDef:2
IsContinuous
boolean
Mandatory
The property shall have value TRUE
Name
string
Mandatory
The property shall have value "DMTF:System Input Power"
ProgrammaticUnits
string
Mandatory
The property shall have value "watt"
SimpleFunction
uint16
Mandatory
The property shall have value 4 (Average)
TimeScope uint16 Mandatory The property shall have value 2 (Point)
7.6.2 DCIM_AggregationMetricValue 587
The following clauses define the requirements for the DCIM_AggregationMetricValue class. 588
DCIM_AggregationMetricValue is a derivation of CIM_AggregationMetricValue. 589
The DCIM_AggrMetricInstance association’s Dependent property shall reference 590
DCIM_AggregationMetricValue instances. 591
The DCIM_MetricForME association’s Dependent property shall reference 592
DCIM_AggregationMetricValue instances. 593
7.6.2.1 Resource URIs for WinRM® 594
The class Resource URI shall be “http://schemas.dell.com/wbem/wscim/1/cim-595
schema/2/DCIM_AggregationMetricValue?__cimnamespace=root/dcim” 596
The key property shall be the InstanceID. 597
The instance Resource URI for this DCIM_AggregationMetricValue instance shall be: 598
http://schemas.dell.com/wbem/wscim/1/cim-schema/2/DCIM_AggregationMetricValue? 599
?__cimnamespace=root/dcim+InstanceID=<InstanceID>” 600
7.6.2.2 Operations 601
The following table details the implemented operations on DCIM_AggregationMetricValue. 602
Table 23 – DCIM_AggregationMetricValue Operations 603
Operation Name
Requirements
Get
Mandatory
Enumerate
Mandatory
Associators
Mandatory
References
Mandatory
7.6.2.3 Properties 604
The following table details the requirements for implementing DCIM_AggregationMetricValue instance 605
representing average power consumption metric in Watts for Last Minute, Hour, Day and Week. The most 606
derived class name of this instance shall be DCIM_AggregationMetricValue. 607
If the column “Property Name” matches the property name, the property either shall have the value 608
denoted in the corresponding column “Additional Requirements, or shall be implemented according to 609
the requirements in the corresponding column “Additional Requirements”. 610
611