White Papers
Version 1.0.0 21
Table 12 – DCIM_AggregationMetricValue: Maximum Power Consumption Metric in Amperes 409
Properties 410
Property Name
Type
Requirement
Additional Requirements
AggregationDuration
datetime
Mandatory
The property shall be in W3C
representation in WS-CIM with
the corresponding value equal to
Current Time minus Start time of
MaxPeak Reading
AggregationTimeStamp
datetime
Mandatory
The property shall be in W3C
representation in WS-CIM with
the corresponding value equal to
Current timestamp.
InstanceID
string
Mandatory
The property shall have value
“DCIM:System:Max:Current:Cont”
MetricDefinitionId
string
Mandatory
The property shall have value
"AggrMetricDef:3"
MetricValue
string
Mandatory
The property shall have value
equal to the MaxPeak Amp
Reading in 100 mAmps.
TimeStamp
datetime
Mandatory
The property shall be in W3C
representation in WS-CIM with
the corresponding value equal to
Current Time
Volatile
boolean
Mandatory
The property shall have value
TRUE
7.4 Maximum Power Consumption Metric for Last Minute, Hour, Day and Week 411
The following defines the requirements of the DCIM_AggregationMetricValue instance for the maximum 412
power consumption metric for last minute, hour, day, and week. 413
One instance of DCIM_AggregationMetricValue shall be instantiated for maximum power consumption 414
last minute. 415
One instance of DCIM_AggregationMetricValue shall be instantiated for maximum power consumption 416
last hour. 417
One instance of DCIM_AggregationMetricValue shall be instantiated for maximum power consumption 418
last day. 419
One instance of DCIM_AggregationMetricValue shall be instantiated for maximum power consumption 420
last week. 421