White Papers
20 Version 1.0.0
GatheringType
uint16
Mandatory
The property shall have value 3 (periodic)
Id
string
Mandatory
The property shall have value “AggrMetricDef:3”
IsContinuous
boolean
Mandatory
The property shall have value TRUE
Name
string
Mandatory
The property shall have value "DMTF:System Input
Power"
ProgrammaticUnits
string
Mandatory
The property shall have value "ampere * 10^-1"
SampleInterval
datetime
Mandatory
The property value shall be in W3C representation in
WS-CIM with the corresponding value equal to CIM
datetime 00000000000500.000000:000.
SimpleFunction
uint16
Mandatory
The property shall have value 3 (Maximum)
TimeScope
uint16
Mandatory
The property shall have value 2 (Point)
7.3.2 DCIM_AggregationMetricValue 385
The following clauses define the requirements for the DCIM_AggregationMetricValue class. 386
DCIM_AggregationMetricValue is a derivation of CIM_AggregationMetricValue. 387
The DCIM_AggrMetricInstance association’s Dependent property shall reference 388
DCIM_AggregationMetricValue instances. 389
The DCIM_MetricForME association’s Dependent property shall reference 390
DCIM_AggregationMetricValue instances. 391
7.3.2.1 Resource URIs for WinRM® 392
The class Resource URI shall be “http://schemas.dell.com/wbem/wscim/1/cim-393
schema/2/DCIM_AggregationMetricValue?__cimnamespace=root/dcim” 394
The key property shall be the InstanceID. 395
The instance Resource URI for this DCIM_AggregationMetricValue instance shall be: 396
“http://schemas.dell.com/wbem/wscim/1/cim-schema/2/DCIM_AggregationMetricValue? 397
?__cimnamespace=root/dcim+InstanceID=<InstanceID>” 398
7.3.2.2 Operations 399
The following table details the implemented operations on DCIM_AggregationMetricValue. 400
Table 11 – DCIM_AggregationMetricValue Operations 401
Operation Name
Requirements
Required Input
Get
Mandatory
Instance URI
Enumerate
Mandatory
Class URI
Associators
Mandatory
Instance URI
References
Mandatory
Instance URI
7.3.2.3 Properties 402
The following table details the requirements for implementing DCIM_AggregationMetricValue instance 403
representing max power consumption metric in amperes. The most derived class name of this instance 404
shall be DCIM_AggregationMetricValue. 405
If the column “Property Name” matches the property name, the property either shall have the value 406
denoted in the corresponding column “Additional Requirements”, or shall be implemented according to 407
the requirements in the corresponding column “Additional Requirements”. 408