White Papers

16 Version 1.0.0
“Peak Watt Power Consumption”
GatheringType
uint16
Mandatory
The property shall have value 3
(periodic)
Id
string
Mandatory
The property is the key and shall
have value “AggrMetricDef:0
IsContinuous
boolean
Mandatory
The property shall have value
TRUE
Name
string
Mandatory
The property shall have value
"DMTF:System Input Power"
ProgrammaticUnits
string
Mandatory
The property shall have value "watt"
SampleInterval
datetime
Mandatory
The property value shall be in W3C
representation in WS-CIM with the
corresponding value equal to CIM
datetime
00000000000500.000000:000.
SimpleFunction
uint16
Mandatory
The property shall have value 3
(Maximum)
TimeScope
uint16
Mandatory
The property shall have value 2
(Point)
7.1.2 DCIM_AggregationMetricValue 293
The following clauses define the requirements for the DCIM_AggregationMetricValue class. 294
DCIM_AggregationMetricValue is a derivation of CIM_AggregationMetricValue. 295
The DCIM_AggrMetricInstance association’s Dependent property shall reference 296
DCIM_AggregationMetricValue instances. 297
The DCIM_MetricForME association’s Dependent property shall reference 298
DCIM_AggregationMetricValue instances. 299
7.1.2.1 Resource URIs for WinRM® 300
The class Resource URI shall be “http://schemas.dell.com/wbem/wscim/1/cim-301
schema/2/DCIM_AggregationMetricValue?__cimnamespace=root/dcim” 302
The key property shall be the InstanceID. 303
The instance Resource URI for this DCIM_AggregationMetricValue instance shall be: 304
http://schemas.dell.com/wbem/wscim/1/cim-schema/2/DCIM_AggregationMetricValue? 305
?__cimnamespace=root/dcim+InstanceID=<InstanceID>” 306
7.1.2.2 Operations 307
The following table details the implemented operations on DCIM_AggregationMetricValue. 308
Table 5 – DCIM_AggregationMetricValue Operations 309
Operation Name
Requirements
Get
Mandatory
Enumerate
Mandatory
Associators
Mandatory
References