7.1.3 Properties
The following table details the implemented properties for DCIM_PowerSupplyView instance representing
a power supply in a system. The “Requirements” column shall denote the implementation requirement for
the corresponding property. If the column “Property Name” matches the property name, the property
either shall have the value denoted in the corresponding column “Additional Requirement”, or shall be
implemented according to the requirements in the corresponding column “Additional Requirement”.
Table 4 – DCIM_PowerSupplyView - Properties
Property Name
Requirements
Type
Requirement and Description
InstanceID
Mandatory
string
The property value shall be the FQDD property
value.
FQDD
Mandatory
string
A string containing the Fully Qualified Device
Description a user-friendly name for the object.
TotalOutputPower
Mandatory
uint32
Shall be in Watts. 0 shall mean “Unknown”.
Represents the total output power of the power
supply in Watts.
InputVoltage
Mandatory
uint32
Shall be in Volts. 0 shall mean “Unknown”. The
input voltage for the supply, in Volts.
PrimaryStatus
Mandatory
uint32
PrimaryStatus provides a high level status
value, intended to align with Red-Yellow-Green
type representation of status.
Type
Mandatory
uint16
PowerSupply Type indicates the device type
(AC/DC - Variable/Regulated) of the power
supply.
DetailedState[]
Mandatory
string
Further status of the power supply.
RedMinNumberNeeded
Mandatory
uint32
0 shall mean Unknown. RedMinNumberNeeded
indicates the smallest number of power supplies
that MUST be operational in order to function in
redundancy.
RedundancyStatus
Mandatory
uint16
The property value shall be one of the following:
0(Unknown), 2 (Fully Redundant), 3(Degraded
Redundancy), 4 (Redundancy Lost).
RedundancyStatus provides information on the
state of the power supply redundancy.
Manufacturer
Mandatory
string
The name of the organization responsible for
producing the power supply.
Model
Mandatory
string
The make and or model of the product.
SerialNumber
Mandatory
string
A manufacturer-allocated number used to
identify the power supply.
PartNumber
Mandatory
string
The part number assigned by the organization
that is responsible for producing or
manufacturing the power supply.
FirmwareVersionString
Mandatory
string
A string containing the power supply’s firmware
version.
LastSystemInventoryTime
Mandatory
string
This property provides the last time \"System
\"Inventory Collection On Reboot(CSIOR)\" was
performed. The value is represented as
yyyymmddHHMMSS.
LastUpdateTime
Mandatory
string
This property provides the last time the data
was updated. The value is represented as
yyyymmddHHMMSS