Users Guide

Power
Environmental
NOTE: For more information about environmental measurements for specific system
configurations, go to www.dell.com/environmental_datasheets.
Operating 10° to 35°C (50° to 95°F) wit h a maximum
temperature gradation of 10°C p er hour
NOTE: For altitudes above 2950 feet, the
maximum operating temperature is derated
1°F/550 ft.
CAUTION: The maximum number of memory
modules and hard drives supported on 1U
and 2U node configurations, with 130W (4
and 8 core) and 135W processors, depends
on the power supply installed.
Storage –40° t o 65°C (–40° t o 149°F) wit h a maximum
temperature gradation of 20°C p er hour
Relative humidity
Operating 20% t o 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
Storage 5% to 95% (noncondensing)
Maximum vibration
Operating 0.26 Grms at 5–350 Hz
Storage 1.88 Grms at 10–500 Hz for 15 min
Maximum shock
Operating One shock pulse in the positive z axis (one pulse
on each side of the syst em) of 31 G for 2.6 ms in
the operational orientation
Storage Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 71 G for up to 2 ms;
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 27 G faired square
wave pulse with velocity change at 235 inches/
second (597 centimeters/second)
Altitude
Operating -15.2 to 3,048 m (-50 t o 10,000 ft.)
Storage -15.2 to 10,668 m (-50 to 35,000 ft.)
41