a) Partially tighten the first screw (approximately 3 turns).
b) Tighten the second screw completely.
c) Return to the first screw and tighten it completely.
If the PHM slips off the blue retention clips when the screws are partially tightened, follow these steps to secure the PHM:
a. Loosen both the heat sink screws completely.
b. Lower the PHM on to the blue retention clips, follow the procedure described in step 2.
c. Secure the PHM to the system board, follow the procedure described in step 43.
NOTE: The processor and heat sink module retention screws should not be tightened to more than 0.13 kgf-m (1.35
N.m or 12 in-lbf).
Figure 56. Installing a processor and heat sink module (1U)
Next steps
1. Follow the procedure listed in After working inside your system.
Internal PERC riser
Removing internal MiniPERC riser
Prerequisites
1. Follow the safety guidelines listed in Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Open the cable guiding latch for easy access.
Steps
1. Open the plunger.
2. Hold the blue touch points and lift the internal MiniPERC riser.