2. Push the blue retention clips inward to allow the heat sink to drop into place.
3. Using the #Torx T30 screwdriver, tighten one screw at a time.
NOTE: Ensure that the screw is tightened completely before moving onto the next screw.
NOTE: The processor and heat sink module retention screws should not be tightened to more than 0.13 kgf-m (1.35
N.m or 12 in-lbf).
Figure 46. Installing the processor and heat sink module (2U)
Figure 47. Installing a processor and heat sink module (1U)
Next steps
1. If removed, install the expansion card risers.
2. If disconnected, connect the cables to the expansion card(s).
3. If applicable, install the air shroud.
4. Follow the procedure listed in After working inside your system on page 57.