Owners Manual

TDP (W)
Processor
model
number
Supported
heat sinks
Max
DIMM
count per
CPU
24x 2.5”
HDDs
enclosure
20x 2.5”
HDDs
enclosure
16x 2.5”
HDDs
enclosure
12x 2.5”
HDDs
enclosure
8x 2.5”
HDDs
enclosure
4x 2.5”
HDDs
enclosure
4114 CPU1:
JYKMM |
CPU2:
V2DRD
CPU1: 8 |
CPU2: 8
35°C/
95°F
35°C/95°F
35°C/
95°F
35°C/95°F 35°C/95°F 35°C/95°F
4112 CPU1:
JYKMM |
CPU2:
V2DRD
CPU1: 8 |
CPU2: 8
35°C/
95°F
35°C/95°F
35°C/
95°F
35°C/95°F 35°C/95°F 35°C/95°F
4110 CPU1:
JYKMM |
CPU2:
V2DRD
CPU1: 8 |
CPU2: 8
35°C/
95°F
35°C/95°F
35°C/
95°F
35°C/95°F 35°C/95°F 35°C/95°F
4108 CPU1:
JYKMM |
CPU2:
V2DRD
CPU1: 8 |
CPU2: 8
35°C/
95°F
35°C/95°F
35°C/
95°F
35°C/95°F 35°C/95°F 35°C/95°F
3106 CPU1:
JYKMM |
CPU2:
V2DRD
CPU1: 8 |
CPU2: 8
35°C/
95°F
35°C/95°F
35°C/
95°F
35°C/95°F 35°C/95°F 35°C/95°F
3104 CPU1:
JYKMM |
CPU2:
V2DRD
CPU1: 8 |
CPU2: 8
35°C/
95°F
35°C/95°F
35°C/
95°F
35°C/95°F 35°C/95°F 35°C/95°F
70 W
4109T
CPU1:
JYKMM |
CPU2:
V2DRD
CPU1: 8 |
CPU2: 8
35°C/
95°F
35°C/95°F
35°C/
95°F
35°C/95°F 35°C/95°F 35°C/95°F
Expanded operating temperature specications
Table 23. Expanded operating temperature
Expanded operating temperature Specications
Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C to 35°C), the
system can operate continuously in temperatures as low as 5°C and as high as
40°C.
For temperatures between 35°C and 40°C, de-rate maximum allowable temperature by
1°C per 175 m above 950 m (1°F per 319 ft).
≤ 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C dew point.
22 Technical specications