Owners Manual

Table 21. Standard operating temperature specications
Standard operating temperature Specications
Temperature ranges (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the
equipment.
NOTE: Some congurations require a lower ambient temperature. For more information, see the following tables.
Table 22. Maximum continuous operating temperature for nonfabric dual processor conguration
TDP (W)
Processor
model
number
Supported
heat sinks
Max
DIMM
count per
CPU
24x 2.5”
HDDs
enclosure
20x 2.5”
HDDs
enclosure
16x 2.5”
HDDs
enclosure
12x 2.5”
HDDs
enclosure
8x 2.5”
HDDs
enclosure
4x 2.5”
HDDs
enclosure
205 W
8180 CPU1:
FMM2M |
CPU2:
V2DRD
CPU1: 6 |
CPU2: 8
Not supported
21°C/
69.8°F
21°C/
69.8°F
21°C/
69.8°F
21°C/
69.8°F
8180M CPU1:
FMM2M |
CPU2:
V2DRD
CPU1: 6 |
CPU2: 8
21°C/
69.8°F
21°C/
69.8°F
21°C/
69.8°F
21°C/
69.8°F
8168 CPU1:
FMM2M |
CPU2:
V2DRD
CPU1: 6 |
CPU2: 8
21°C/
69.8°F
21°C/
69.8°F
21°C/
69.8°F
21°C/
69.8°F
200 W
6154
CPU1:
FMM2M |
CPU2:
V2DRD
CPU1: 6 |
CPU2: 8
22°C/
71.6°F
22°C/
71.6°F
22°C/
71.6°F
22°C/
71.6°F
165 W
6150 CPU1:
JYKMM |
CPU2:
V2DRD
CPU1: 8 |
CPU2: 8
30°C/
86°F
30°C/86°F 30°C/86°F 35°C/95°F
6146 CPU1:
JYKMM |
CPU2:
V2DRD
CPU1: 6 |
CPU2: 8
30°C/
86°F
30°C/86°F 30°C/86°F 35°C/95°F
8176 CPU1:
JYKMM |
CPU2:
V2DRD
CPU1: 8 |
CPU2: 8
30°C/
86°F
30°C/86°F 30°C/86°F 35°C/95°F
8176M CPU1:
JYKMM |
CPU2:
V2DRD
CPU1: 8 |
CPU2: 8
30°C/
86°F
30°C/86°F 30°C/86°F 35°C/95°F
8170M CPU1:
JYKMM |
CPU2:
V2DRD
CPU1: 8 |
CPU2: 8
30°C/
86°F
30°C/86°F 30°C/86°F 35°C/95°F
Technical specications 19