Users Guide

DSU fails and displays an error message as "Invalid System ID" on re-branded systems.
Update of SAS-RAID firmware and OS collector fails when multiple-updates scheduled via iDRAC or iDRAC
Passthrough.
In such scenarios update the failed components individually.
Segmentation error is observed when the option rsystemtype or when --use-idrac-passthrough is mentioned
in config file.
In some scenarios segmentation fault is observed for multiple remote connection through iDRAC.
Recommendation: If the issue persists, user has to re-try the command.
Firmware updates via iDRAC or iDRAC passthrough with a non-admin user displays an error as 0 Updates
Succeeded.
Reason for this error might be with insufficient privileges, refer DSU log file to confirm same. Perform the update using iDRAC
user with Administrator privileges.
DSU functionality fails for the system when the iDRAC was configured with non-default HTTPS port using iDRAC
USB-NIC passthrough
Change the iDRAC HTTPS port to default (443) and retry the updates.
DSU installed system environmental variable "PATH" is not getting cleared during uninstallation
When DSU is used in remote scenarios, DSU installed system environmental variable "PATH" is not getting cleared during
uninstallation. If multiple remote sessions are used for the same machine the entry created by DSU will get accumulated due to
this.
Workaround : Delete multiple entries of DSU path.
Incorrect network Firmware name displayed for iDRAC and iDRAC-pass-through with preview with iDRAC version
3.36.36.36
Displays incorrect firmware name for iDRAC and iDRAC-pass-through.
Recommendation :Use latest iDRAC version.
Frequently asked questions
79