Release Notes
Version Affected:
Dell System Update version1.8.0
Issue 20(158771):
Description:
Downgrade for Dell Update Package, Intel Adapter Firmware (FW-DUP) from 19.0.x to 18.8.x is not supported. Hence, downgrade will
always be shown in preview mode of DSU even after performing downgrade.
Issue 21(147822):
Description:
IDSDM DUP (Firmware_FF4WY_WN64_1.7_A02.EXE) may show update status as "not applied, dependent component requires restart"
even if dependent component does not require reboot. Overall update is still success.
Issue 22(162745):
Description:
Emulex Fibre Channel component may be listed as BIOS for 14G PowerEdge servers.
Issue 23(162736):
Description:
Chipset driver component may fail to show in the update list for R7425 platform for Windows 2016 and Windows 2019 OS
Issue 24(159413):
Description:
Network firmware version may be displayed partially on RHEL 6.10
Issue 25(154905):
Description:
Display name for Mellanox ConnectX-4 card may be displayed partially in the inventory output.
Issue 26(160597):
Description:
Standard NVM Express Controller Driver (CFYMV) does not support Non-RAID config. Hence may fail to update using DSU.
Version Affected:
ALL
Known Issues