Owners Manual
Table Of Contents
- PowerVault NX3240 Network Attached Storage System Installation and Service Manual
- Contents
- NX3240 system overview
- Technical specifications
- Initial system setup and configuration
- Pre-operating system management applications
- Options to manage the pre-operating system applications
- System Setup
- Viewing System Setup
- System Setup details
- System BIOS
- Viewing System BIOS
- System BIOS Settings details
- System Information
- Viewing System Information
- System Information details
- Memory Settings
- Viewing Memory Settings
- Memory Settings details
- Processor Settings
- Viewing Processor Settings
- Processor Settings details
- SATA Settings
- Viewing SATA Settings
- SATA Settings details
- Boot Settings
- Viewing Boot Settings
- Boot Settings details
- Choosing system boot mode
- Changing boot order
- Integrated Devices
- Viewing Integrated Devices
- Integrated Devices details
- Serial Communication
- Viewing Serial Communication
- Serial Communication details
- System Profile Settings
- Viewing System Profile Settings
- System Profile Settings details
- System Security
- Viewing System Security
- System Security Settings details
- Creating a system and setup password
- Using your system password to secure your system
- Deleting or changing system and setup password
- Operating with setup password enabled
- Miscellaneous Settings
- Viewing Miscellaneous Settings
- Miscellaneous Settings details
- iDRAC Settings utility
- Device Settings
- Dell Lifecycle Controller
- Boot Manager
- PXE boot
- Installing and removing system components
- Safety instructions
- Before working inside your system
- After working inside your system
- Recommended tools
- Front bezel
- System cover
- Backplane cover
- Air shroud
- Cooling fan assembly
- Cooling fans
- Intrusion switch
- Mid drive tray
- Removing the mid drive tray
- Installing the mid drive tray
- Removing a drive blank from the drive carrier
- Installing a drive blank into the drive carrier
- Removing a drive carrier from the mid drive tray
- Installing a drive carrier into the mid drive tray
- Removing a 3.5-inch drive from the drive carrier
- Installing a 3.5-inch drive into the drive carrier
- Drives
- Removing a drive blank
- Installing a drive blank
- Removing a drive carrier
- Installing a drive carrier
- Removing a 2.5-inch drive from the 3.5-inch drive adapter
- Installing a 2.5-inch drive into the 3.5-inch drive adapter
- Removing a 3.5-inch adapter from a 3.5-inch drive carrier
- Installing a 3.5-inch adapter into a 3.5-inch drive carrier
- Removing the drive from the drive carrier
- Installing a drive into the drive carrier
- Rear drive cage
- System memory
- Processors and heat sinks
- Expansion cards and expansion card risers
- Expansion card installation guidelines
- Opening and closing the PCIe card holder latch
- Removing the expansion card from the expansion card riser
- Installing the expansion card into the expansion card riser
- Removing the riser 2 blank
- Installing the riser 2 blank
- Removing the expansion card riser 1
- Installing the expansion card riser 1
- Removing the expansion card riser 2
- Installing the expansion card riser 2
- Network daughter card
- Integrated storage controller card
- Backplane
- System battery
- Power supply units
- System board
- Trusted Platform Module
- Control panel
- Diagnostics and indicators
- Jumpers and connectors
- Getting help
Figure 19. Installing the cooling fan assembly
NOTE: The images shown here are for representation only and the actual configuration of your system may vary.
Next steps
Follow the procedure listed in After working inside your system.
Cooling fans
Cooling fans are integrated into the system to dissipate the heat generated by the system. These fans provide cooling for the
processors, expansion cards, and memory modules.
Your system supports up to six high performance hot swappable cooling fans.
For single processor systems without a mid drive tray, only four cooling fans are required. Fan bays 1 and 2 are covered by a fan
blank.
NOTE:
Each fan is listed in the systems management software, referenced by the respective fan number. If there is a
problem with a particular fan, you can easily identify and replace the proper fan by noting the fan numbers on the cooling
fan assembly.
Table 5. Fan support matrix for NX3240
Front
Storage
PSU type CPU count Fan1 Fan2 Fan3 Fan4 Fan5 Fan6
8 x 3.5-inch Cable PSU
or
Redundant
PSU
1 Not required Required Required Required Required Not required
Redundant
PSU
2 Not required Required Required Required Required Required
Installing and removing system components 57