Release Notes

Dell - Internal Use - Confidential
You cannot run on a 64-bit Red Hat Enterprise Linux operating system on SUU because SUU is a 32-bit
application.
The work around is: Defect DF452489
Manually install the following RPMs:
glibc.i686
compat-libstdc++.i686
libstdc++.i686
zlib.i686
libxml2.i686
libXp.i686
libXtst.i686
ncurses-libs
pam.i686
If you login to a system running on Microsoft Windows Small Business Server 2008 operating system, by
default you are logged in as a regular user even though you may have Administrator privileges. This is due to
an in-built feature called User Account Control (UAC) that automatically reduces the potential of security
breaches. Before you run SUU on your system, elevate the privileges for administrators using Windows
security options in Group Policy Editor. For more information, see the SUU User's Guide.
Defect DF452489 - Export comparison report, in the file Dialogbox mouse movements are sluggish
To work around the issue, ddd the following line:
"*.multiClickTime: 500" to the file ~/.Xdefaults and run xrdb -merge ~/.Xdefaults
Defect DF497677 - If an update fails while updating multiple devices of same type, the comparison report
shows that the current version is updated for all entries of the selected type.
On all versions of the ESX, following USB connection error messages are generated, these messages can be
ignored.
A typical message is:
Vendor: iDRAC Model: MAS022 Rev: 1.00
Type: Direct-Access ANSI SCSI revision: 02
Vendor: iDRAC Model: SECUPD Rev: 0329
Type: Direct-Access ANSI SCSI revision: 02