after running the command.
VRTX M520 is displayed as M520 in SUU Comparison report.
VRTX M620 is displayed as M620 in SUU Comparison report.
The BIOS package is not available for T105 platform. (BITS089778)
Intel firmware and driver is not supported on AQUA platform. (BITS209784)
The 13G SEP firmware DUP {SWB# GWJRF} won’t work on more than 8 HDD backplane system
configurations.
Hard drive update is not supported in HBA mode.
When updating multiple, identical devices on the same system, SUU applies the latest update to all instances
of all devices. For example, if the system is configured with three controllers configured with firmware or
driver versions 1.2, 1.3, and 1.4, and the repository version is 1.4, SUU applies version 1.4 to all instances of all
devices.(136620)
When you run SUU using the "-p" option, SUU reports the current instance log location ("suu -p") instead of
the SUU instance log location ("suu -u") that is performing the update.(135925)
If a NIC teaming application is installed on the system, SUU updates only the NIC base driver, if the driver is
compatible with the teaming application. To verify driver compatibility, run DUP on the system to update the
driver and read the generated messages.(138648)
Devices that are disabled in the operating system are not inventoried or updated by SUU. To update or
inventory these devices, enable the devices in the operating system and then re-launch SUU. (142111)
Do not use the RAC/iDRAC virtual media to remotely run SUU on a system. This procedure ends the virtual
media connection, resulting in an unsuccessful SUU update.(144487)
SUU update is unsuccessful if SUU is run from a pathname that contains special characters such as,",:,/,\,$,
and so on. It is recommended to use a directory name without any special characters for running SUU. For
example, when a USB DVD-ROM or USB disk is attached, to a system running SUSE Linux Enterprise Server
operating system, mounts it to a directory name that contains special characters. For example,
/media/USB:1:2/. (42279)
In Linux, if there is no space in the var partition or tmp folder, SUU displays the following error message:
"Not enough space available in the /var or /tmp folder. Please ensure you have atleast 1.5GB.
"Ensure that you have sufficient space in the var partition or tmp folder and reboot SUU to start the system
inventory.(66118)
In some cases, where the latest Intel NIC driver (Intel PRO PCIE Gigabit Family of Adapters 9.5, base driver
version 9.6.31.0) is installed as part of Dell Systems Build and Update Utility (SBUU) install, SUU may not be
able to inventory the respective NIC. This happens because SBUU would not have installed the umbrella
software. In these cases, install the umbrella with the umbrella installer (available at dell.com/support or in the
SERVICE directory in the Dell Systems Management Tools and Documentation DVD).(DF130363)