Severity Alert Cause Dell PRO Tip
Recommended Remedial
Action
2307 Bad block table is full. Critical The bad block table is the
table used for remapping
bad disk blocks.
Restrict
2310 A virtual disk is
permanently degraded
Critical A redundant virtual disk
has lost redundancy. This
may occur when the
virtual disk suers the
failure of more than one
physical disk.
Restrict and Migrate
2312 A power supply in the
enclosure has an AC
failure
Warning The power supply has an
AC failure.
Restrict
2313 A power supply in the
enclosure has a DC failure
Warning The power supply has a
DC failure.
Restrict
2314 The initialization
sequence of SAS
components failed during
system startup. SAS
management and
monitoring is not
possible.
Critical Storage Management is
unable to monitor or
manage SAS devices.
Restrict and Migrate
2318 Problems with the
battery or the battery
charger have been
detected. The battery
health is poor.
Warning The battery or the battery
charger is not functioning
properly.
Restrict
2319 Single-bit ECC error on
controller DIMM. The
DIMM is degrading.
Warning The dual in-line memory
module (DIMM) is
beginning to malfunction.
Restrict and Migrate
2320 Single-bit ECC error. The
DIMM is critically
degraded.
Critical The DIMM is
malfunctioning. Data loss
or data corruption may be
imminent.
Restrict and Migrate
2321 Single-bit ECC error. The
controller DIMM is
nonfunctional. There will
be no further reporting
Critical The dual in-line memory
module (DIMM) is
malfunctioning. Data loss
or data corruption is
eminent.
Restrict and Migrate
2322 The DC power supply is
switched o
Critical The power supply unit is
switched o. Either a user
switched o the power
supply unit or it is
defective.
Restrict and Migrate
2324 The AC power supply
cable has been removed
Critical The power cable may be
pulled out or removed. The
power cable may also have
Restrict and Migrate
Using Dell EMC Server Performance Resource Optimization Pack 23