Users Guide

Dell Event ID Alert Description on
Operations Manager and
PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended Remedial
Action
2283 A redundant path is
broken
Warning The controller has two
connectors that are
connected to the same
enclosure.
Restrict and Migrate
2289 Multi-bit ECC error on
controller DIMM
Critical An error involving multiple
bits has been encountered
during a read or write
operation.
Restrict and Migrate
2290 Single-bit ECC error on
controller DIMM
Warning An error involving a single
bit has been encountered
during a read or write
operation.
Restrict
2292 Communication with the
enclosure has been lost
Critical The controller has lost
communication with an
enclosure management
module (EMM). The
cables may be loose or
defective.
Restrict and Migrate
2293 EMM (Enclosure
Management Module)
Failure
Error The failure may be caused
by a loss of power to the
EMM.
Restrict and Migrate
2298 The enclosure has a bad
sensor
Warning The enclosure has a bad
sensor. The enclosure
sensors monitor the fan
speeds, temperature
probes, and so on.
Restrict
2299 Bad PHY Critical There is a problem with a
physical connection or
PHY.
Restrict
2300 Unstable Enclosure
Failure
Critical The controller is not
receiving a consistent
response from the
enclosure.
Restrict and Migrate
2301 Enclosure Hardware Error Critical The enclosure or an
enclosure component is in
a Failed or Degraded state.
Restrict and Migrate
2302 The enclosure is not
responding
Critical The enclosure or an
enclosure component is in
a Failed or Degraded state.
Restrict and Migrate
2306 Bad block table is 80%
full
Warning The bad block table is the
table used for remapping
bad disk blocks. This table
lls as bad disk blocks are
remapped.
Restrict
22 Using Dell EMC Server Performance Resource Optimization Pack