Users Guide
Dell Event ID Alert Description on
Operations Manager and
PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended Remedial
Action
redundancy. In the case of
a virtual disk, one or more
physical disks included in
the virtual disk have failed.
2246 The controller battery is
degraded
Warning The temperature of the
battery is high. This may
be due to the battery
being charged.
Restrict
2264 A device is missing Warning The controller cannot
communicate with a
device. The device may be
removed.
Restrict
2265 A device is in an unknown
state
Warning The controller cannot
communicate with a
device. The state of the
device cannot be
determined.
Restrict and Migrate
2268 Storage Management
communication Error
Critical Storage Management has
lost communication with a
controller. This may occur
if the controller driver or
rmware is experiencing a
problem.
Restrict and Migrate
2272 Patrol Read found an
uncorrectable media error
Critical The Patrol Read task has
encountered an error that
cannot be corrected.
There may be a bad disk
block that cannot be
remapped.
Restrict and Migrate
2273 A block on the physical
disk has been punctured
by the controller
Critical The controller encountered
an unrecoverable medium
error when attempting to
read a block on the
physical disk and marked
that block as invalid.
Restrict and Migrate
2278 The controller battery
charge level is below a
normal threshold.
Warning The controller battery
cannot maintain sucient
charge level to function
properly or the battery is
discharging.
Restrict
2282 Hot spare SMART polling
failed
Warning The controller rmware
attempted to do SMART
polling on the hot spare
but was not able to
complete the SMART
polling.
Restrict and Migrate
Using Dell EMC Server Performance Resource Optimization Pack 21