Users Guide

Dell Event ID Alert Description on
Operations Manager and
PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended Remedial
Action
2145 Controller battery low Warning The controller battery
charge is low.
Restrict
2169 The controller battery
needs to be replaced
Critical The controller battery
cannot recharge. The
battery may have been
already recharged the
maximum number of
times. In addition, the
battery charger may not
be working.
Restrict and Migrate
2171 The controller battery
temperature is above
normal
Warning The room temperature
may be too hot. The
system fan may also be
degraded or failed.
Restrict
2174 The controller battery has
been removed
Warning The controller cannot
communicate with the
battery. The battery may
be removed or the contact
point maye degraded
Restrict and Migrate
2178 The controller battery
Learn cycle has timed out
Warning The controller battery
must be fully charged
before the Learn cycle can
begin.
Restrict
2187 Single-bit ECC error limit
exceeded on the
controller DIMM
Warning The controller memory is
malfunctioning.
Restrict and Migrate
2201 A global hot spare failed Warning The controller is not able
to communicate with a
disk that is assigned as a
global hot spare. The disk
may have failed or been
removed.
Restrict
2203 A dedicated hot spare
failed
Warning The controller is not able
to communicate with a
disk that is assigned as a
dedicated hot spare.
Restrict
2206 The only hot spare
available is a SATA disk.
SATA disks cannot
replace SAS disks
Warning The only physical disk
available to be assigned as
a hot spare is using SATA
technology.
Restrict
2207 The only hot spare
available is a SAS disk.
SAS disks cannot replace
SATA disks
Warning The only physical disk
available to be assigned as
a hot spare is using SAS
technology.
Restrict
2213 Recharge count
maximum exceeded
Warning A virtual disk or an
enclosure has lost data
Restrict
20 Using Dell EMC Server Performance Resource Optimization Pack