Users Guide

Dell Event ID Alert Description on
Operations Manager and
PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended Remedial
Action
state and processor sensor
status are provided.
1605;5605 Processor sensor
detected a non-
recoverable value
Error A processor sensor in the
specied system has
failed. The sensor location,
chassis location, previous
state and processor sensor
status are provided.
Restrict and Migrate
1703;5703 Battery sensor detected a
warning value
Warning A battery sensor in the
specied system detected
that a battery is in
a predictive failure state.
Restrict
1704;5704 Battery sensor detected a
failure value
Error A battery sensor in the
specied system detected
that a battery has failed.
The sensor location,
chassis location, previous
state, and battery sensor
status information is
provided.
Restrict
1705;5705 Battery sensor detected a
non-recoverable value
Error A battery sensor in the
specied system could not
retrieve a value. The
sensor location, chassis
location, previous state,
and battery sensor status
information is provided.
Restrict
2048 Device Failed Error Critical A storage component such
as a physical disk or an
enclosure has failed. The
failed component may
have been identied by the
controller while performing
a task such as a rescan or
a check consistency.
Restrict and Migrate
2056 Virtual Disk Failed Critical One or more physical disks
included in the virtual disk
have failed.
Restrict and Migrate
2057 Virtual Disk Degraded
Warning
Warning This alert message occurs
when a physical disk
included in a redundant
virtual disk fails.
Restrict
2076 Virtual Disk Check
Consistency Failed
Critical A physical disk included in
the virtual disk failed or
there is an error in the
parity information.
Restrict and Migrate
18 Using Dell EMC Server Performance Resource Optimization Pack