Users Guide
Dell Event ID Alert Description on
Operations Manager and
PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended Remedial
Action
redundant unit has been
disconnected, has failed,
or is not present. The
redundancy unit location,
chassis location, previous
redundancy state, and the
number of devices
required for full
redundancy are provided.
1353;5353 Power supply detected a
warning
Warning A power supply sensor
reading in the specied
system exceeded denable
warning threshold.
Restrict
1354;5354 Power supply detected a
failure
Error A power supply has been
disconnected or has failed.
Restrict
1355;5355 Power supply sensor
detected a non-
recoverable value
Error A power supply sensor in
the specied system
detected an error from
which it cannot recover.
The sensor location,
chassis location, previous
state, power supply type,
additional power supply
status, and conguration
error type information is
provided.
Restrict
1403;5403 Memory Device Status
Warning
Warning A memory device
correction rate exceeded
an acceptable value.
Restrict
1404;5404 Memory Device Error Error A memory device
correction rate exceeded
an acceptable value, a
memory spare bank was
activated, or a multibit
ECC error occurred.
Restrict and Migrate
1405;5405 Memory device status is
non-recoverable
Error Memory device status is
nonrecoverable. The
memory module failed
because of an
irrecoverable error.
Restrict and Migrate
1453;5453 Fan enclosure removed
from system
Warning A fan enclosure has been
removed from the
specied system. The
sensor and chassis
location information is
provided.
Restrict