Users Guide

Dell Event ID Alert Description on
Operations Manager and
PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended Remedial
Action
1204;5204 Current sensor detected
a failure value
Error A current sensor in the
specied system exceeded
its failure threshold value.
Restrict and Migrate
1205;5205 Current sensor detected
a non-recoverable value
Error A current sensor in the
specied system detected
an error from which it
cannot recover. The
sensor location, chassis
location, previous state,
and current sensor value
are provided.
Restrict and Migrate
1253;5253 Chassis intrusion in
progress
Warning A chassis intrusion sensor
in the specied system
detected that a system
cover is currently being
opened and the system is
operating. The sensor
location, chassis location,
previous state, and chassis
intrusion state information
is provided.
Restrict
1254;5254 Chassis intrusion
detected
Critical A chassis intrusion sensor
in the specied system
detected that the system
cover was opened while
the system was operating.
The sensor location,
chassis location, previous
state, and chassis intrusion
state information is
provided.
Restrict and Migrate
1305;5305 Redundancy degraded Warning A redundancy sensor in
the specied system
detected that one of the
components of the
redundancy unit has failed
but the unit is still
redundant. The
redundancy unit location,
chassis location, previous
redundancy state, and the
number of devices
required for full
redundancy information is
provided.
Restrict
1306;5306 Redundancy lost Error A redundancy sensor in
the specied system
detected that one of the
components in the
Restrict
Using Dell EMC Server Performance Resource Optimization Pack 15