Users Guide
Dell Event ID Alert Description on
Operations Manager and
PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended Remedial
Action
specied system exceeded
its failure threshold value.
1055;5055 Temperature sensor
detected a non-
recoverable value
Error A temperature sensor on
the backplane board,
system board, or drive
carrier in the specied
system detected an error
from which it cannot
recover. The sensor
location, chassis location,
previous state, and
temperature sensor value
information is provided.
Restrict and Migrate
1104;5104 Fan sensor detected a
failure value
Error A fan sensor in the
specied system detected
the failure of one or more
fans.
Restrict
1105;5105 Fan sensor detected a
non-recoverable value
Error A fan sensor detected an
error from which it cannot
recover. The sensor
location, chassis location,
previous state, and fan
sensor value information is
provided.
Restrict
1153;5153 Voltage sensor detected
a warning value
Warning A voltage sensor in the
specied system exceeded
its warning threshold. The
sensor location, chassis
location, previous state,
and voltage sensor value
information is provided.
Restrict
1154;5154 Voltage sensor detected
a failure value
Error A voltage sensor in the
specied system exceeded
its failure threshold value.
Restrict and Migrate
1155;5155 Voltage sensor detected
a non-recoverable value
Error A voltage sensor in the
specied system detected
an error from which it
cannot recover. The
sensor location, chassis
location, previous state,
and voltage sensor value
information is provided.
Restrict and Migrate
1203;5203 Current sensor detected
a warning value
Warning A current sensor in the
specied system exceeded
its warning threshold
value.
Restrict
14 Using Dell EMC Server Performance Resource Optimization Pack