Users Guide

Dell Event ID Alert Description on
Operations Manager and
PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended Remedial
Action
specied system exceeded
its failure threshold value.
1055;5055 Temperature sensor
detected a non-
recoverable value
Error A temperature sensor on
the backplane board,
system board, or drive
carrier in the specied
system detected an error
from which it cannot
recover. The sensor
location, chassis location,
previous state, and
temperature sensor value
information is provided.
Restrict and Migrate
1104;5104 Fan sensor detected a
failure value
Error A fan sensor in the
specied system detected
the failure of one or more
fans.
Restrict
1105;5105 Fan sensor detected a
non-recoverable value
Error A fan sensor detected an
error from which it cannot
recover. The sensor
location, chassis location,
previous state, and fan
sensor value information is
provided.
Restrict
1153;5153 Voltage sensor detected
a warning value
Warning A voltage sensor in the
specied system exceeded
its warning threshold. The
sensor location, chassis
location, previous state,
and voltage sensor value
information is provided.
Restrict
1154;5154 Voltage sensor detected
a failure value
Error A voltage sensor in the
specied system exceeded
its failure threshold value.
Restrict and Migrate
1155;5155 Voltage sensor detected
a non-recoverable value
Error A voltage sensor in the
specied system detected
an error from which it
cannot recover. The
sensor location, chassis
location, previous state,
and voltage sensor value
information is provided.
Restrict and Migrate
1203;5203 Current sensor detected
a warning value
Warning A current sensor in the
specied system exceeded
its warning threshold
value.
Restrict
14 Using Dell EMC Server Performance Resource Optimization Pack