Figure 6. Override Properties
Alerts and Recovery Actions
The following table lists the alerts and the recommended remedial actions:
Table 2. Alerts and Recovery Actions
Dell Event ID Alert Description on
Operations Manager and
PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended Remedial
Action
1004;5004 Thermal shutdown
protection has been
initiated
Error This message is generated
when a system is
congured for thermal
shutdown due to an error
event. If a temperature
sensor reading exceeds
the error threshold for
which the system is
congured, the operating
system shuts down and
the system powers o.
This event may also be
initiated on certain
systems when a fan
enclosure is removed from
the system for an
extended period of time.
Restrict and Migrate
1053;5053 Temperature sensor
detected a warning value
Warning A temperature sensor on
the backplane board,
system board, CPU, or
drive carrier in the
specied system exceeded
its warning threshold
value.
Restrict
1054;5054 Temperature sensor
detected a failure value
Error A temperature sensor on
the backplane board,
system board, CPU, or
drive carrier in the
Restrict and Migrate