Users Guide

Table 2. Alerts and Recovery Actions (continued)
Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO
Tip Recommended
Remedial Action
2355 Enclosure firmware
download failed.
Warning The system was unable
to download firmware
to the enclosure. The
controller may have lost
communication with the
enclosure. There may
have been problems with
the data transfer or the
download media may be
corrupt.
Restrict and Migrate
2356 SAS SMP
communications error
Critical The text for this
alert is generated
by the firmware and
can vary depending
on the situation. The
reference to SMP in
this text refers to SAS
Management Protocol.
Restrict
2357 SAS expander error Critical There may be a problem
with the enclosure.
Verify the health of
the enclosure and its
components.
Restrict
2387 Virtual disk bad block
medium error is
detected
Error Virtual disk bad blocks
are due to presence
of unrecoverable bad
blocks on one or more
member physical disks.
Restrict and Migrate
2396 The Check
Consistency detected
uncorrectable multiple
medium errors
Critical Medium errors in the
physical drives.
Restrict
2397 The Check
Consistency
completed with
uncorrectable errors
Critical Medium errors in the
physical drives.
Restrict and Migrate
2416 Disk medium error
detected
Warning Disk medium error
detected.
Restrict
2417 There is an
unrecoverable medium
error detected on
virtual disk
Error Unrecoverable medium
error detected on virtual
disk.
Restrict and Migrate
2,4 Driver Name:
b06bdrv,ebdrv
b57w2k,b57nd60x,
b57nd60a,l2nd
Dell OMNIC Broadcom
Network Interface
Link Down
Critical The network link is
down.
Restrict
13,27,29,70 Driver
Name: e1express,
e1qexpress, ixgbe,
e1000
Dell OMNIC Intel
Network Interface
Link Down
Critical Link has been
disconnected.
Restrict
2699 OMSS-FluidCache
communications
Failure
Critical The communications
connection between
OMSS and the Fluid
Restrict and Migrate
24 Using Dell EMC Server Performance Resource Optimization Pack