Table 2. Alerts and Recovery Actions (continued)
Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO
Tip Recommended
Remedial Action
2324 The AC power supply
cable has been
removed
Critical The power cable may be
pulled out or removed.
The power cable may
also have overheated
and become warped and
nonfunctional.
Restrict and Migrate
2327 The NVRAM has
corrupted data.
The controller is
reinitializing the
NVRAM
Warning The NVRAM has
corrupted data. This may
occur after a power
surge, a battery failure,
or for other reasons. The
controller is reinitializing
the NVRAM.
Restrict and Migrate
2328 The NVRAM has
corrupt data
Warning The NVRAM has corrupt
data. The controller is
unable to correct the
situation.
Restrict and Migrate
2329 SAS port report Warning The text for this
alert is generated by
the controller and can
vary depending on the
situation.
Restrict and Migrate
2337 The controller is
unable to recover
cached data from the
battery backup unit
(BBU)
Critical The controller was
unable to recover data
from the cache.
Restrict
2340 The background
initialization (BGI)
completed with
uncorrectable errors
Critical The background
initialization task
encountered errors that
cannot be corrected.
Restrict and Migrate
2342 The Check
Consistency found
inconsistent parity
data. Data redundancy
may be lost
Warning The data on a source
disk and the redundant
data on a target disk are
inconsistent.
Restrict and Migrate
2347 The rebuild failed due
to errors on the
source physical disk
Error It is not possible to
rebuild data that resides
on a defective disk.
Restrict and Migrate
2348 The rebuild failed due
to errors on the target
physical disk.
Error It is not possible to
rebuild data that resides
on a defective disk.
Restrict and Migrate
2349 A bad disk block could
not be reassigned
during a write
operation
Critical A write operation could
not complete because
the disk contains bad
disk blocks that could
not be reassigned. Data
loss may have occurred.
Restrict
2350 There was an
unrecoverable disk
media error during the
rebuild or recovery
operation
Critical The rebuild or recovery
operation encountered
an unrecoverable disk
media error.
Restrict