Table 2. Alerts and Recovery Actions (continued)
Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO
Tip Recommended
Remedial Action
2278 The controller battery
charge level is below a
normal threshold.
Warning The controller battery
cannot maintain
sufficient charge level to
function properly or the
battery is discharging.
Restrict
2282 Hot spare SMART
polling failed
Warning The controller firmware
attempted to do SMART
polling on the hot spare
but was not able to
complete the SMART
polling.
Restrict and Migrate
2283 A redundant path is
broken
Warning The controller has two
connectors that are
connected to the same
enclosure.
Restrict and Migrate
2289 Multi-bit ECC error on
controller DIMM
Critical An error involving
multiple bits has been
encountered during a
read or write operation.
Restrict and Migrate
2290 Single-bit ECC error
on controller DIMM
Warning An error involving a
single bit has been
encountered during a
read or write operation.
Restrict
2292 Communication with
the enclosure has
been lost
Critical The controller has lost
communication with an
enclosure management
module (EMM). The
cables may be loose or
defective.
Restrict and Migrate
2293 EMM (Enclosure
Management Module)
Failure
Error The failure may be
caused by a loss of
power to the EMM.
Restrict and Migrate
2298 The enclosure has a
bad sensor
Warning The enclosure has a bad
sensor. The enclosure
sensors monitor the
fan speeds, temperature
probes, and so on.
Restrict
2299 Bad PHY Critical There is a problem with
a physical connection or
PHY.
Restrict
2300 Unstable Enclosure
Failure
Critical The controller is not
receiving a consistent
response from the
enclosure.
Restrict and Migrate
2301 Enclosure Hardware
Error
Critical The enclosure or an
enclosure component is
in a Failed or Degraded
state.
Restrict and Migrate
2302 The enclosure is not
responding
Critical The enclosure or an
enclosure component is
in a Failed or Degraded
state.
Restrict and Migrate
Using Dell EMC Server Performance Resource Optimization Pack 21