Users Guide

Table 2. Alerts and Recovery Actions (continued)
Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO
Tip Recommended
Remedial Action
2203 A dedicated hot spare
failed
Warning The controller is not able
to communicate with a
disk that is assigned as
a dedicated hot spare.
Restrict
2206 The only hot spare
available is a SATA
disk. SATA disks
cannot replace SAS
disks
Warning The only physical disk
available to be assigned
as a hot spare is using
SATA technology.
Restrict
2207 The only hot spare
available is a SAS
disk. SAS disks cannot
replace SATA disks
Warning The only physical disk
available to be assigned
as a hot spare is using
SAS technology.
Restrict
2213 Recharge count
maximum exceeded
Warning A virtual disk or an
enclosure has lost data
redundancy. In the case
of a virtual disk, one
or more physical disks
included in the virtual
disk have failed.
Restrict
2246 The controller battery
is degraded
Warning The temperature of the
battery is high. This may
be due to the battery
being charged.
Restrict
2264 A device is missing Warning The controller cannot
communicate with a
device. The device may
be removed.
Restrict
2265 A device is in an
unknown state
Warning The controller cannot
communicate with a
device. The state of
the device cannot be
determined.
Restrict and Migrate
2268 Storage Management
communication Error
Critical Storage Management
has lost communication
with a controller. This
may occur if the
controller driver or
firmware is experiencing
a problem.
Restrict and Migrate
2272 Patrol Read found an
uncorrectable media
error
Critical The Patrol Read task
has encountered an
error that cannot be
corrected. There may be
a bad disk block that
cannot be remapped.
Restrict and Migrate
2273 A block on the
physical disk has been
punctured by the
controller
Critical The controller
encountered an
unrecoverable medium
error when attempting
to read a block on the
physical disk and marked
that block as invalid.
Restrict and Migrate
20 Using Dell EMC Server Performance Resource Optimization Pack