Table 2. Alerts and Recovery Actions (continued)
Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO
Tip Recommended
Remedial Action
additional power supply
status, and configuration
error type information is
provided.
1403;5403 Memory Device Status
Warning
Warning A memory device
correction rate exceeded
an acceptable value.
Restrict
1404;5404 Memory Device Error Error A memory device
correction rate exceeded
an acceptable value, a
memory spare bank was
activated, or a multibit
ECC error occurred.
Restrict and Migrate
1405;5405 Memory device status
is non-recoverable
Error Memory device status
is nonrecoverable.
The memory module
failed because of an
irrecoverable error.
Restrict and Migrate
1453;5453 Fan enclosure
removed from system
Warning A fan enclosure has
been removed from
the specified system.
The sensor and chassis
location information is
provided.
Restrict
1454;5454 Fan enclosure
removed from system
for an extended
amount of time
Error A fan enclosure has
been removed from the
specified system for
a user-definable length
of time. The sensor
and chassis location
information is provided.
Restrict and Migrate
1455;5455 Fan enclosure sensor
detected a non-
recoverable value
Error A fan enclosure sensor
in the specified system
detected an error from
which it cannot recover.
The sensor and chassis
location are provided.
Restrict and Migrate
1503;5503 AC power has been
lost
Error An AC power cord has
lost its power, and lack
of redundancy requires
this to be classified as an
error.
Restrict and Migrate
1504;5504 AC power cord has
lost its power
Error Power supply is
disrupted to the AC
power cord or an
AC power cord is
not transmitting power,
and lack of redundancy
requires this to be
classified as an error.
The sensor and chassis
location information is
provided.
Restrict and Migrate
16 Using Dell EMC Server Performance Resource Optimization Pack