Users Guide

Table 2. Alerts and Recovery Actions (continued)
Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO
Tip Recommended
Remedial Action
sensor location, chassis
location, previous state,
and fan sensor value
information is provided.
1153;5153 Voltage sensor
detected a warning
value
Warning A voltage sensor
in the specified
system exceeded its
warning threshold. The
sensor location, chassis
location, previous state,
and voltage sensor value
information is provided.
Restrict
1154;5154 Voltage sensor
detected a failure
value
Error A voltage sensor in
the specified system
exceeded its failure
threshold value.
Restrict and Migrate
1155;5155 Voltage sensor
detected a non-
recoverable value
Error A voltage sensor
in the specified
system detected an
error from which it
cannot recover. The
sensor location, chassis
location, previous state,
and voltage sensor value
information is provided.
Restrict and Migrate
1203;5203 Current sensor
detected a warning
value
Warning A current sensor in
the specified system
exceeded its warning
threshold value.
Restrict
1204;5204 Current sensor
detected a failure
value
Error A current sensor in
the specified system
exceeded its failure
threshold value.
Restrict and Migrate
1205;5205 Current sensor
detected a non-
recoverable value
Error A current sensor
in the specified
system detected an
error from which it
cannot recover. The
sensor location, chassis
location, previous state,
and current sensor value
are provided.
Restrict and Migrate
1253;5253 Chassis intrusion in
progress
Warning A chassis intrusion
sensor in the specified
system detected that a
system cover is currently
being opened and the
system is operating. The
sensor location, chassis
location, previous state,
and chassis intrusion
state information is
provided.
Restrict
14 Using Dell EMC Server Performance Resource Optimization Pack