Alerts and Recovery Actions
The following table lists the alerts and the recommended remedial actions:
Table 2. Alerts and Recovery Actions
Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO
Tip Recommended
Remedial Action
1004;5004 Thermal shutdown
protection has been
initiated
Error This message is
generated when a
system is configured
for thermal shutdown
due to an error
event. If a temperature
sensor reading exceeds
the error threshold
for which the system
is configured, the
operating system shuts
down and the system
powers off. This event
may also be initiated on
certain systems when a
fan enclosure is removed
from the system for an
extended period of time.
Restrict and Migrate
1053;5053 Temperature sensor
detected a warning
value
Warning A temperature sensor
on the backplane board,
system board, CPU,
or drive carrier in
the specified system
exceeded its warning
threshold value.
Restrict
1054;5054 Temperature sensor
detected a failure
value
Error A temperature sensor
on the backplane board,
system board, CPU,
or drive carrier in
the specified system
exceeded its failure
threshold value.
Restrict and Migrate
1055;5055 Temperature sensor
detected a non-
recoverable value
Error A temperature sensor
on the backplane board,
system board, or drive
carrier in the specified
system detected an
error from which it
cannot recover. The
sensor location, chassis
location, previous state,
and temperature sensor
value information is
provided.
Restrict and Migrate
1104;5104 Fan sensor detected a
failure value
Error A fan sensor in
the specified system
detected the failure of
one or more fans.
Restrict
1105;5105 Fan sensor detected a
non-recoverable value
Error A fan sensor detected
an error from which
it cannot recover. The
Restrict
Using Dell EMC Server Performance Resource Optimization Pack 13