Users Guide
NOTE: PowerVault servers are not supported for iDRAC Service Module (iSM).
For more information about discovering Dell EMC devices, see Discovering a Dell EMC PowerEdge Server
For more information about using the iDRAC access via Host OS, see the Integrated Dell Remote Access Controller7/8/9 with
Lifecycle Controller User’s Guide at Dell.com/idracmanuals.
Compare Scalable and Detailed Editions of Dell EMC Server and Rack
Workstation Monitoring (Licensed)
The following table helps you understand the environment in which you can use Scalable and Detailed Edition features.
Table 22. Scalable Management Pack Versus Detailed Management Pack
Features Scalable Edition Detailed Edition
Dell EMC Server and Rack
Workstation Monitoring (Licensed)
● Inventory up to individual components.
● Health monitoring at server, Rack
Workstation and component group
level.
● Inventory and health monitoring of
individual components.
● View metrics for power, temperature,
and network interface cards,
processor, memory, Compute Usage
per Second (CUPS), PCIe SSD wear
percentage and IO performance
metrics.
Discover and classify Dell EMC PowerEdge Servers through iDRAC–WS-
MAN
The Dell EMC OMIMSSC enables you to discover and classify Dell EMC PowerEdge Server.
The following table lists the details of the hardware discovery and grouping by the Dell EMC Server and Rack Monitoring
(Licensed) feature through iDRAC–WS-MAN:
Table 23. Dell Hardware Discovery and Grouping
Group Diagram View Hardware Type
Dell EMC PowerEdge Server Dell EMC Monolithic Servers
Dell EMC Modular Servers
Dell EMC Sled Group
Dell PowerEdge systems
Dell PowerVault systems
Dell EMC Rack Workstation Dell EMC Rack Workstation Diagram Dell Precision Racks
Discover Dell EMC PowerEdge Servers using iDRAC-WSMAN through OMIMSSC
appliance
You can discover the Dell EMC PowerEdge Servers using iDRAC-WSMAN through OMIMSSC appliance dashboard by using an
IP address or an IP range. To discover servers, provide the iDRAC IP address and the device type credentials of a server. When
you are discovering servers by using an IP range, specify an IP (IPv4) range within a subnet by including the start and end
range.
NOTE:
Ensure that one of the Alert Destination fields in the iDRAC SNMP Traps and Email Settings list is completely
blank. This ensures the automatic setting of the SNMP trap destination during device discovery. With the SNMP Monitoring
account configured in SCOM, the Dell EMC Servers and Rack Workstation (licensed) alert view displays the SNMP
alerts from iDRAC. For more information about configuring iDRAC trap destination, see www.dell.com/iDRACmanuals.
To discover the Dell EMC PowerEdge servers:
1. In Dell EMC OMIMSSC, click Monitoring > Server View, and then click Discover.
Dell EMC OMIMSSC supported monitoring features
69