Release Notes
Description: The appliance device discovery job that is triggered gets stuck in the running task for a long time (more than 5
hrs) in the OMIMSSC Appliance.
Resolution: Create the discovery task again in Console UI for same set of IPs with a different job name.
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
● Issue 19
Description: When there are multiple Operations Manager consoles in a Management group., the device credential profiles
and jobs that are created from the Dell EMC OpenManage Integration Dashboard when launched from one Operations
Manager console are not visible from the Dell EMC OpenManage Integration Dashboard when launched from an alternative
Operations Manager console within the Management group
Resolution:
1. If the user wants to use the same device credential profile created, then launch the Dell EMC OpenManage Integration
Dashboard from the Operations Manager console where it was created initially.
2. New device credential profile can be created from Dell EMC OpenManage Integration Dashboard that is launched from an
alternative Operations Manager console can be used for discovery of devices.
3. If the user wants to view the scheduled jobs or the job history, then launch the Dell EMC OpenManage Integration
Dashboard from the Operations Manager console where it was created initially.
NOTE: Ensure that the device credential profile names and jobs names are unique.
Version affected: Dell EMC OpenManage Integration v7.2 for Microsoft System Center for Operations Manager.
● Issue 20
Description: When you de-enroll the SCOM Management group from the OMIMSSC appliance and enroll a new SCOM
Management group within the same OMIMSSC appliance, you try to reuse the same job name or credential profile name as
used earlier. You see an error that the credential profile or the job exists.
Resolution: Ensure not to use same job name and same credential profile as used earlier.
Version affected: Dell EMC OpenManage Integration v7.2 for Microsoft System Center for Operations Manager.
● Issue 21
Description: When the monitoring level is changed using Dell EMC Feature Management Dashboard task pane and Sync with
MSSC is performed from the Dell EMC OpenManage Integration Dashboard, then the monitoring level is affected in the
consecutive discovery cycle but not immediately.
Resolution: Wait for the monitoring level to be changed and reflected after next discovery cycle. or change the discovery
mode from the Dell EMC OpenManage Integration Dashboard directly, and then the device discovery jobs get scheduled
immediately.
Version affected: Dell EMC OpenManage Integration v7.2 for Microsoft System Center for Operations Manager.
● Issue 22
Description: In the SCOM console, the overall status of fan group shows critical for Dell EMC VRTX Chassis in the Dell EMC
VRTX Chassis Diagram View. However, the detailed diagram view shows only healthy fans but not the unhealthy fans.
Resolution: Launch the CMC Product URL from the inventory of the CMC devices.
Version affected: Dell EMC OpenManage Integration v7.2 for Microsoft System Center for Operations Manager.
● Issue 23
Description: When the Management server(MS) is removed from the SCOM management group that had been used for
enrollment in the OMIMSSC Admin Portal, the Dell EMC Feature Management Dashboard shows blank on the remaining
MSes.
Resolution:
1. Launch the MS that had been removed from the management group.
2. Click the lower left start button to open the Start menu. Type cmd, and then select Command Prompt: Run reg
export HKEY_LOCAL_MACHINE\SOFTWARE\Dell\Dell Server Management Pack Suites
c:\Export.txt.
3. Now, launch any of the MS in the management group.
4. Copy the exported file c:\Export.txt to the MS.
5. Go to the Start Menu, type cmd, and then select command prompt : Run reg import c:\Export.txt.
6. Set the override value to FQDN of the MS by performing the below steps:
12