Release Notes

Description: If the unreachable IP addresses are given for discovery, then discovery for those devices runs periodically and
task that is created by OMIMSSC appliance cannot be deleted for them.
Resolution: If provided credentials are wrong, then use edit credentials profile page to correct them.
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
Issue 11
Description: In Chassis inventory, the IP address may not be updated for the I/O module.
Resolution: None
Version affected: All (Dell EMC Chassis Monitoring Feature (Detailed), Firmware 5.0.1)
Issue 12
Description: After the reboot of appliance, monitoring will not happen until next discovery which was scheduled to be done
for that particular device. Thus, health update can take up to 24 hours to occur.
Resolution: Use Configuration override page to change only discovery override after reboot. This will ensure discovery to
happen immediately, and then Health Unit Monitors will also be updated in next default cycle.
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
Issue 13
Description: If the Modular servers which are correlated to a Chassis slot are removed from the Operations Manager
monitoring, the main server object may still be shown.
Resolution: None
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager (Chassis
Modular Server Correlation, Dell EMC Server and Rack Workstation Monitoring, Dell EMC Server and Rack Workstation
Monitoring Feature (Licensed)).
Issue 14
Description: If the Dell EMC PowerEdge Servers are discovered through sync operation in OMIMSSC appliance and if in the
next discovery, port or credentials are changed, discovery of such a device in Appliance will fail in the consequent discovery
cycles and resolve sync errors page will not show this device.
Resolution: None
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
Issue 15
Description: Names for Groups, object discoveries, KB articles, and Feature name column of Feature Management Dashboard
are not changed to Dell EMC.
Resolution: None
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
Issue 17
Description: When FM/FC blades that are present in an FX2/FX2s chassis where the "Chassis Management at Server node"
is set to Manage and monitor are discovered from the Dell EMC OpenManage Integration dashboard, the Power supply and
Fan sensor groups are shown as sub components of the server. Post this if the "Chassis Management at Server node" set to
None or disabled from the iDRAC console of the blade server, then in the consequent discoveries the Power supply group
and the Fan sensor are retained with health state as Warning to indicate an unknown health state of the groups.
Resolution: None
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
Issue 17
Description: If after enrollment of Dell EMC OpenManage Integration Dashboard in the Operations Manager console is not
launching or if after the enrollment, there is any change in Appliance IP.
Resolution: Update the OMIMSSC appliance IP in Dell EMC SDK Override Appliance IP Unit monitor override.
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
Issue 18