Release Notes

Resolution: Close and reopen the Operations Manager console.
Version affected: All
Issue 2
Description: Despite updating the default port number, CMC, or DRAC running firmware version 3.0 returns the wrong URL.
Resolution: None
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager (Dell EMC
Chassis Monitoring and DRAC Monitoring Feature).
Issue 3
Description: Dell EMC PowerEdge Servers that are discovered through the Dell EMC Server and Rack Workstation
Monitoring feature are shown with the default logical device icon.
Resolution: None
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager (Dell EMC
Server and Rack Workstation Monitoring Feature).
Issue 4
Description: If the component is under a Software RAID controller, Inventory for Bus Type and Media Protocol in Virtual Disk
are not supported.
Resolution: Refer the iDRAC documentation for updated support.
Version affected: All
Issue 5
Description: The Fan components of the Dell EMC PowerEdge M1000e chassis are displayed as Dell Fan.
Resolution: Upgrade the Dell EMC PowerEdge M1000e firmware to version 5.0.1.
Version affected: All
Issue 6
Description: Inventory field Manufacturer for SATA Disks may be incorrectly reported as ATA.
Resolution: None
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
Issue 7
Description: NIC Inventory field for Virtual MAC Address is displayed as "00:00:00:00:00:00," when Virtual MAC Address has
not been configured for the NIC. This issue affects the Dell EMC Server and Rack Workstation Monitoring (Licensed)
feature in version 6.3 and the out of band or the agent-based monitoring feature of versions 6.0 and later.
Resolution: None
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
Issue 8
Description: When Dell EMC PowerEdge M1000e chassis is discovered with controller who is inserted in slot2, and slot1 is
empty, then the value of the firmware version is displayed as Not Applicable.
Resolution: Insert the controller in SLOT1.
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
Issue 9
Description: The Deletion of devices from appliance to Operations Manager can take a long time depending on the number of
devices that are deleted at a time.
Resolution: Select small set of devices for deletion at a time. Wait for few minutes after the completion of a deletion task
and then go to trigger the next deletion.
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
Issue 10
10