Users Guide

Table Of Contents
Event rules processed by the licensed (iDRAC WS-Man) monitoring
feature of OMIMSSC for PowerEdge servers and workstations
Dell Systems Event Processing Rules
OMIMSSC processes rules from Dell EMC PowerEdge Servers.
Dell EMC PowerEdge Servers through iDRACWS-Man
All informational, warning, and critical SNMP traps for Dell EMC PowerEdge Servers discovered using Dell EMC Server and Rack
Monitoring (Licensed) feature, have a corresponding SNMP trap rule. Each of these rules is processed based on the following
criteria:
Source Name = Dell Server IP
OID = Actual trap ID of the trap event
Data Provider = SNMP trap event provider
Event rules processed by the licensed Chassis monitoring feature of
OMIMSSC
Dell Systems Event Processing RulesThe Dell EMC Server Management Pack Suite processes rules from Chassis traps.
Dell EMC Chassis devicesAll informational, warning, and critical SNMP traps for the chassis devices have a corresponding
SNMP trap rule. Each of these rules is processed based on the following criteria:
Source Name = DRAC/CMC name or IP
OID = Actual trap ID of the DRAC or CMC SNMP trap event
Data Provider = SNMP trap
NOTE:
Informational alerts are turned off by default. To receive these alerts, import informational alerts management
pack.
Reference topics 97