Users Guide

Table Of Contents
Troubleshooting
Topics:
After deploying the OMIMSSC appliance, an IP address is not assigned to the OMIMSSC appliance
After deploying the OMIMSSC appliance, enrollment of management servers with OMIMSSC is unsuccessful or the
management packs are not successfully installed.
Unable to start the OpenManage Integration Dashboard in the SCOM console
Unable to connect to the OMIMSSC appliance
Issues observed when usernames of local account and domain account match but the passwords differ
Resolve issues in synchronizing data of Dell EMC devices with OMIMSSC
Manually clean the SCOM console that is unreachable during the de-enrollment
Connection is unavailable between OMIMSSC and the SCOM console
Unable to log in to the OMIMSSC Admin portal by using the Mozilla Firefox browser
A job run on OMIMSSC to discover a device stays in the Progress state for more than five hours
Unable to discover and monitor devices after restarting OMIMSSC
Event ID 33333: Data Access Layer rejected retry on SqlError
Resolve issues in the Dell EMC Feature Management Dashboard
After deploying the OMIMSSC appliance, an IP
address is not assigned to the OMIMSSC appliance
After creating and starting the appliance, the IP address is not assigned or displayed on the Command Line Interface (CLI).
WorkaroundCheck if the virtual switch, which is mapped to a physical switch, is configured correctly, and then connect to the
OMIMSSC appliance.
After deploying the OMIMSSC appliance, enrollment
of management servers with OMIMSSC is
unsuccessful or the management packs are not
successfully installed.
Workaround:
While deploying the OMIMSSC appliance, ensure that Synchronize guest time with host option on the VM is enabled.
While configuring OMIMSSC VM network settings, under IPv4 CONFIGURATION, if you are assigning a Static IP address,
enter the IP address and save the changes. Re-open the Configure Network option on the CLI and change the hostname.
See Configure OMIMSSC VM network settings on page 24.
Unable to start the OpenManage Integration
Dashboard in the SCOM console
After enrollment, the OpenManage Integration Dashboard is not loading in the SCOM console, or if there is any change in the
OMIMSSC Appliance IP.
WorkaroundUpdate the OMIMSSC appliance IP under Unit Monitors:
20