Users Guide
Dell EMC Performance and Power Monitoring Views through iDRAC–WS-MAN
NOTE:
• System Board Usage metrics are supported only on some of the 13th generation of the PowerEdge servers. For more information
on performance information collection, see View Dell EMC servers performance collection rules set on Operations Manager. Also,
enable the Dell EMC Server Performance rule.
• Dell EMC Performance View displays the performance index of CPU, memory, I/O utilization, and system level CUPS index in a
graphical format.
To view the performance and power monitoring on the Operations Manager console:
1 Launch the Operations Manager console and click Monitoring.
2 In the Monitoring pane, click Dell EMC > Dell EMC Performance and Power Monitoring Views for the following views:
• Dell EMC Performance View
• Disk Performance - Licensed (%)
NOTE: All performance metric rules are disabled by default for Dell EMC Server and Rack Workstation Monitoring
(Licensed) feature.
3 To view the System Board Usage metrics, click Dell EMC Performance and Power Monitoring Views > Dell EMC System Board
Usage
for the following views:
• CPU Usage (%)
• IO Usage (%)
• Memory Usage (%)
• Overall System Usage (%)
4 Select the counters from the individual performance views and select the time range for the values required.
The data collected is represented in a graphical format for each system.
A unit monitor, monitors the performance counter over two successive cycles to check if it exceeds a threshold value. When the threshold
value is exceeded, the server changes state and generates an alert. This unit monitor is disabled by default. You can override (enable) the
threshold values from the Authoring pane of the Operations Manager console. Unit monitors are available under the Dell Server objects for
the Licensed monitoring feature. To enable the threshold values of unit monitors, see Enabling Performance and Power Monitoring Unit
Monitors.
For more information on performance information collection, see View Dell EMC servers performance collection rules set on Operations
Manager.
Enabling Performance and Power Monitoring Unit Monitors
To enable the unit monitors for Performance and Power Monitoring Views:
1 Launch Operations Manager console and click Authoring.
2 Click Management Pack Objects > Monitors, and then search for Performance in the Look for: eld.
3 Click Dell Server > Performance.
4 Right-click the unit monitor you want to enable.
5 Select Overrides > Override the Monitor and select an option based on your requirement.
For example, to override the unit monitors for all objects of class: Dell Server, select For all objects of class: Dell Server
The Override Properties screen is displayed.
6 Select Enabled and set the Override Value to True.
7 Under Management Pack, either select a management pack created from the Select destination management pack: drop-down
menu or create a management pack.
To create a management pack:
80
Dell EMC OMIMSSC version 7.1 supported monitoring features