5 Select Network Switches > Install > Run.
The Dell EMC Network Switch Management packs are imported.
NOTE: In case you want to Reinstall or repair the existing Management packs, follow the above steps for importing.
NOTE: To delete the imported Management packs, select Network Switches > Uninstall > Run. All the imported Management
packs for the Dell network switches are deleted.
Discover and classify Dell EMC Network Switch using Dell
EMC OMIMSSC Operations Manager
The Dell EMC OpenManage Integration for Microsoft System Center Operations Manager enables you to discover and classify Dell EMC
Network switches such as M-Series, Z-Series, N-Series, and S-Series switches.
The following table lists the details of the hardware discovery and grouping by the Network switch monitoring feature:
Table 33. Dell hardware discovery and grouping
Group Diagram View Hardware type
Dell EMC Network Switch Dell EMC Network Switch Diagram Views Switch instances on the network, switch,
and its components.
Discovering Dell EMC Network switches using Dell EMC OMIMSSC
Import the Dell EMC Network Switch Management Pack into the Operations Manager from OMIMSSC.
You can discover the switches by using an IP address or an IP range. To discover switches, provide the switch IP address and the device
credential prole of the switch. When you are discovering switches by using an IP range, specify an IP (IPv4) range (within a subnet) by
including the start and end IP in the range.
To discover a switch:
1 In OMIMSSC, perform the following steps:
• On the navigation pane, click Monitoring > Network Switch View > Discover.
2 In the Discover page, select the required option:
• Discover Using an IP Address—to discover a switch using an IP address.
• Discover Using an IP Range—to discover multiple switches using an IP range.
3 In Discover Using an IP Address or IP Address Range, do the following:
• In IP Address Start Range, and IP Address End Range, provide the IP address range of the switches you want to discover, which
includes the start and end IP range.
• (Optional) Select Enable Exclude Range if you want to exclude an IP address range.
In IP Address Start Range and IP Address End Range, provide the range that you want to exclude.
4 In Apply this Credential Prole, select the device type credential prole.
The selected prole is applied to all the switches.
5 Select the device credential prole, or click Create New to create a device credential prole.
The selected credential prole is applied to discover the switch or switches.
6 Select the Device Credential Prole in the credential type.
The Credentials elds get enabled.
Dell EMC OMIMSSC version 7.1 supported monitoring features