Install Guide
NOTE: In the Event log, ignore the errors pertaining to reimporting of existing management packs under the error logs. These
errors occur when Dell EMC Feature Management Dashboard reimports all the dependent management packs that are already
imported while importing a monitoring feature.
NOTE: Wait for a task to complete (view the state update change in the dashboard) before launching another task using the Dell
EMC Feature Management Dashboard.
Table 21. Feature Management tasks
Tasks Description
Set to Scalable Monitoring
If the Detailed feature is running on the system, the Dell EMC
Feature Management Dashboard switches from the detailed
feature to the scalable feature.
On upgrading from the previous version, run this task to use the
latest version for this monitoring feature.
Set to Detailed Monitoring
If the scalable feature is running on the system, the Dell EMC
Feature Management Dashboard switches from the scalable
feature to the detailed feature.
Refresh Node Count
Updates the node count.
Refresh Dashboard
Updates the Dell EMC Feature Management Dashboard.
NOTE: The Refresh dashboard task may not update the
dashboard immediately; it might take a few minutes to
update the dashboard contents.
Dell EMC Chassis Modular Server Correlation Feature
Chassis Modular Server Correlation feature supports:
• Correlation of discovered Modular Servers using the licensed or license-free monitoring feature with Chassis slots.
NOTE
: Dell EMC Chassis Management Controller/OpenManage Enterprise Modular (CMC/OME-M) slot discovery is
disabled by default. Hence, enable CMC/OME-M slot discovery for the correlation feature to work.
• Correlation of Chassis Shared Storage components with Dell EMC PowerEdge Servers.
NOTE
: Imports Dell EMC Chassis detailed monitoring for the correlation of chassis shared components with Dell EMC
PowerEdge Servers.
Management Packs
After the Dell EMC Server Management Pack management packs are successfully imported, the required management packs should
appear in the Administration pane of the Operations Manager console. For more information, see Importing Management Packs into the
Operations Manager.
Table 22. Dell EMC Chassis Modular Server Correlation monitoring feature and required Management Packs
Feature Default Location of Management Packs Required Management Packs
Dell EMC Chassis Modular
Server Correlation
Library Library
• Dell.Connections.HardwareLibrary.mp
• Dell.OperationsLibrary.Common.mp
Dell EMC OMIMSSC version 7.1 supported monitoring features 49