Install Guide
• Ensure that there is WS-MAN (WS-Management) connectivity between the Management Server and the Managed Node.
Dell EMC Chassis Monitoring requirements
• For slot discovery and correlation to work; ensure that you have Dell Device Helper utility installed.
• To monitor Chassis controller, IO Module, IO Module Group, Power Supply, and Power Supply Group components.
• To monitor the health of Chassis devices, associate the community string Run As account with the SNMP Monitoring Account with
the target as Dell Modular Chassis class or respective Chassis object (if you have dierent Run As accounts for dierent Chassis
devices).
• To discover Chassis Slots and Chassis Slot Summary for Dell EMC Chassis Management Controller/OpenManage Enterprise Modular
(CMC/OME-M); create Run As Accounts and associate it to the proles — Dell CMC Login Account Run As Proles. Also, enable the
CMC Slot Discovery from the Operations Manager console. For more information, see Conguring Chassis Management Controller
feature for Correlating Server Modules with Chassis Slot Summary.
• To perform Chassis Detailed monitoring; create Run As Accounts with WS-MAN credentials required for accessing the Dell EMC CMC/
OME-Ms, and associate it to the proles — Dell CMC Login Account Run As Proles.
NOTE:
• If you are using AD domain credentials for Dell EMC CMC/OME-M, then, enter the credentials in the following format:
username@domainname.com
Conguring Dell EMC Chassis Management Controller/
OpenManage Enterprise Modular (CMC/OME-M) feature for
correlating Server Modules with the Chassis Slot summary
To congure Dell EMC Chassis Management Controller/OpenManage Enterprise Modular (CMC/OME-M) feature for correlating server
modules, create Run As Accounts and associate it to Run As Proles to populate chassis slot summary.
1 Create a Run As Account of type Simple Authentication that has privileges to connect to the CMC/OME-M on the chassis. Also, use
the Basic or Digest Run As Account types for conguring the user credentials.
2 Select the More Secure or Less Secure option in the Run As Account conguration, so that you can selectively distribute the
conguration to specic management servers.
For information about creating a Run As Account of type Simple Authentication, see the “Creating A Simple Authentication Run As
Account” section of Dell EMC OpenManage Integration version 7.1 for Microsoft System Center for Operations Manager User's Guide
at Dell.com/OMConnectionsEnterpriseSystemsManagement.
NOTE
: Add the Server Management Action account to the Operations Manager administrator group.
3 Associate the created Run As Accounts with the Dell CMC Login Account prole and select the appropriate class, group, or object on
which you can congure the prole.
• To enable slot summary discovery for CMC/OME-M, override the enable property to True in Dell CMC Slot Discovery. It is
disabled by default.
NOTE
: After the slot discovery, if you remove the link between Run As Account with Run As Prole, or disable the slot-
discovery workow, the discovered slots remain with old data.
Feature Management tasks
The following table lists the Dell EMC Chassis monitoring tasks available on the Dell EMC Feature Management Dashboard. Some tasks
listed in the Feature Management tasks table appear only after you have imported the Dell EMC Chassis monitoring feature.
48
Dell EMC OMIMSSC version 7.1 supported monitoring features