Release Notes
Resolution: Use Configuration override page to change only discovery override after reboot. This will ensure discovery to happen
immediately and then Health Unit Monitors will also be updated in next default cycle.
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
• Issue 14
Description: If the Modular servers which are correlated to a Chassis slot are removed from the Operations Manager monitoring, the
main server object may still be shown.
Resolution: None
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager (Chassis Modular
Server Correlation, Dell EMC Server and Rack Workstation Monitoring, Dell EMC Server and Rack Workstation Monitoring Feature
(Licensed)).
• Issue 15
Description: If the Dell EMC PowerEdge Servers are discovered through sync operation in OMIMSSC appliance and if in the next
discovery, port or credentials are changed, discovery of such a device in Appliance will fail in the consequent discovery cycles and
resolve sync errors page will not show this device.
Resolution: None
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
• Issue 16
Description: Names for Groups, object discoveries, KB articles, and Feature name column of Feature Management Dashboard are not
changed to Dell EMC.
Resolution: None
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
• Issue 17
Description: When FM/FC blades that are present in an FX2/FX2s chassis where the "Chassis Management at Server node" is set to
Manage and monitor are discovered from the Dell EMC OpenManage Integration dashboard, the Power supply and Fan sensor groups
are shown as sub components of the server. Post this if the "Chassis Management at Server node" set to None or disabled from the
iDRAC console of the blade server, then in the consequent discoveries the Power supply group and the Fan sensor are retained with
health state as Warning to indicate an unknown health state of the groups.
Resolution: None
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
• Issue 18
Description: If after enrollment of Dell EMC OpenManage Integration Dashboard in the Operations Manager console is not launching or
if after the enrollment, there is any change in Appliance IP.
Resolution: Update the OMIMSSC appliance IP in Dell EMC SDK Override Appliance IP Unit monitor override.
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
• Issue 19
Description: The appliance device discovery job that is triggered gets stuck in the running task for a long time (more than 5 hrs) in the
OMIMSSC Appliance.
Resolution: Create the discovery task again in Console UI for same set of IP's with a different job name.
Version affected: Dell EMC OpenManage Integration v7.1 for Microsoft System Center for Operations Manager.
Limitations
1. The detection of unresponsive Chassis Management Controller feature is not supported for 13G FX2 chassis that is discovered
through iDRAC Service Module (iSM) using Windows Management Instrumentation (WMI).
2. Setting preferred monitoring feature through Dell EMC Feature Management Dashboard is not applicable to Dell EMC PowerEdge
Server discovered under Dell EMC Server and Rack Workstations (Licensed) State View via OMIMSSC.
Installation Procedure
To install the Dell EMC Server Management Pack Suite 7.1, deploy the Dell EMC OMIMSSC 7.1 available as .vhd and enroll the
Management Server in OMIMSSC Appliance Web Console. For detailed installation, pre-requisites, configuration, upgrade and
10
Dell EMC OpenManage Integration Version 7.1.1 for Microsoft System Center for Operations Manager (SCOM) Release Notes