Users Guide

Table Of Contents
Figure 7. Dell EMC Chassis Management Controllers Group diagram
For discovered Dell EMC CMC chassis, enable slot discovery which is disabled by default to view:
The occupied and free slot summary in the Chassis Slots Summary
The slot-inventory details modified on CMC chassis that are reflected in the Diagram View.
The correlation of discovered Dell EMC PowerEdege Servers using Licensed or license-free monitoring feature with the slots
of CMC chassis that are displayed in the Dell EMC Chassis Management Controllers Group diagram. The Dell EMC
PowerEdge server is visible under the slot in the diagram.
NOTE:
Create Run As Account for CMC/OME-M slot discovery with simple, basic, or digest authentication only. For more
information, see "Configuring the Dell Chassis Management Controller Feature for Correlating Server Modules with Chassis
Slot Summary" section of the Dell EMC OpenManage Integration Version 7.1.1 for Microsoft System Center for Operations
Manager Installation Guide at Dell.com/support/home.
NOTE: The iDRAC firmware of the modular systems should be compatible with the CMC firmware, failing which, the
Service Tag is displayed as Not Available and the Chassis Blade correlation may not be possible.
Dell EMC Chassis Diagram views
The Dell EMC Chassis diagram view offers a graphical representation of PowerEdge MX7000, PowerEdge FX2, PowerEdge
M1000E chassis, and PowerEdge VRTX chassis devices. Select a component in the diagram to view its details in the Detail
View pane.
Dell EMC Performance and Power Monitoring Views
NOTE:
Dell EMC Chassis Performance View is available only when the detailed feature of the Dell EMC Chassis
Monitoring feature is installed, and you have selected Metrics Monitoring as Yes while overriding the metrics parameters.
For more information on overriding the metrics parameters, see Overriding Dell EMC Chassis discovery parameters,
performance, and health metrics.
To view the performance and power monitoring on the Operations Manager console:
1. Launch the Operations Manager console, and click Monitoring.
2. In the Monitoring pane, click Dell EMC > Dell EMC Performance and Power Monitoring Views to view:
Dell EMC Chassis Performance View
3. Select the counters from the individual performance views and select the time range for which the values are required. The
data collected is represented in a graphical format for each system.
94