Users Guide

Table Of Contents
Overriding Dell EMC Chassis discovery parameters, performance, and health
metrics
You can customize the discovery of Dell EMC chassis by overriding their discovery parameters, performance, and health
metrics.
To override discovery parameters, performance and health metrics:
1. Log in into the Operations Manager console.
2. On the left hand pane, Click Monitoring > Dell EMC > Dell EMC OpenManage Integration Views > OpenManage
Integration Dashboard .
The Dell EMC OMIMSSC console login page is displayed.
3. In Username, type the username. Type the username in the format: domain\username.
4. In Password, type the password, and click Login.
The Overview page is displayed.
5. Select Profiles and Configuration > Configuration Configuration.
The Discovery, Monitoring and Performance Overrides page is displayed.
6. Click Edit.
The Override discovery, monitoring and performance intervals wizard is displayed.
7. In the Override discovery, monitoring and performance intervalspage, you can perform following actions:
a. Under the Device Type list, select the Chassis check box.
b. In the Discovery Type drop-down list, select the discovery mode.
c. Under the Discovery Interval (Seconds), enter the discovery interval in seconds.
d. Under the Health Interval (Seconds), enter the health interval in seconds.
e. In the Metrics Monitoring drop-down list, select Yes to use metrics monitoring, and No if you do not want to use
metrics monitoring.
NOTE: Metrics Monitoring is enabled only when you discover the Chassis devices in Detailed discovery mode.
f. Under the Metrics Interval (Seconds), enter the metrics interval in seconds.
8. To save your settings, click Apply, or to cancel, click Cancel.
Monitoring
You can use the Monitoring pane of the Operations Manager to select views that provide complete health information of the
discovered Dell EMC Chassis Management Controller/OpenManage Enterprise Modular (CMC/OME-M) devices. The Dell EMC
Chassis monitoring feature discovers and monitors the health of the Dell CMC/OME-M devices. The Severity Level Indicators
indicates the health of the Dell CMC/OME-M devices on the network.
Chassis Monitoring includes monitoring the health of the Dell chassis devices, both at regular intervals and on occurrence of
events.
NOTE:
To perform the Dell EMC Chassis Detailed monitoring, associate the WS-MAN credentials Run As account required
for accessing the Dell CMCs with the target as Dell Modular Chassis class or respective CMC object (if you have different
Run As accounts for different CMC/OME-M devices) to the profileDell CMC Login Account Run As Profile
Monitored hardware components
The following table provides information on the monitored hardware components supported in Scalable and Detailed feature.
Table 30. Monitored hardware components Scalable and Detailed feature.
Hardware Components
PowerEdge
MX7000
PowerEdge
M1000e
PowerEdge FX2 PowerEdge VRTX
Scalabl
e
Detailed Scalabl
e
Detailed Scalabl
e
Detailed Scalabl
e
Detaile
d
CMC/OME-M Slot Information
Yes Yes Yes Yes Yes Yes Yes Yes
CMC/OME-M Slot
Yes Yes Yes Yes Yes Yes Yes Yes
Dell EMC OMIMSSC supported monitoring features 91